Multímetro Digital de Campo de Alta Precisión de 60.000 cuentas.
Premiado con el Good Design Award 2013
Display de doble lectura
Filtro de componentes armónicas
Sistema mecánico de protección que impide la inserción errónea de las puntas en el equipo
Medición de señales compuestas AC+DC
Comunicación USB
Temperatura
Frecuencia
Capacidad
Intérprete de 4-20mA a %
DC voltage |
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. |
AC voltage 45 to 65 Hz |
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz |
DC + AC voltage 45 to 65 Hz |
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz |
Resistance |
60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only) |
DC current |
600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. |
AC current 45 to 65 Hz |
600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) |
AC Current (use with Clamp on probes) 40 to 1 kHz |
N/A |
Peak |
DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) |
C (capacitance) |
1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. |
Continuity Check |
Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more |
Diode test |
Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages |
Frequency |
AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) |
dB conversion |
Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages |
Temperature |
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) (use with optional probe DT4910) |
Other functions |
Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion |
Display |
Main and Sub displays: 5-digits LCD, max. 60000 digits |
Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) |
Power supply |
LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours |
Dimensions and mass |
93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) |
Accessories |
Test Lead L9207-10 ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 |